Volume 27, Issue 1 (3-2003)                   Research in Medicine 2003, 27(1): 23-27 | Back to browse issues page

XML Persian Abstract Print


Abstract:   (14511 Views)
Abstract Background: There are various methods for morphine extraction and detection, for this, Thin Layer Chromatography (TLC) is a useful tool. The most common detection technique of TLC plates is slit scanning densitometry. The aim of the present study was to compare the ability of a solid phase extraction (SPE) system with liquid-liquid extraction (LLE) for urinary detection of morphine by a TLC scanner. Materials and methods: Ten urine samples were collected from opioid abusers and each sample was divided in 4 two fractions were extracted by the SPE system and the other two were extracted by LLE technique (Choloroform/2-Propanol, shaking and centrifugation). One sample of each fraction was hydrolysed. Finally, all samples were quantitatively analyzed by TLC-scanner. Results: Results have revealed that the area under curve (AUC) on hydrolyzed samples was higher than nonhydrolyzed ones. Conclusion: Both techniques have showed better results for hydrolyzed samples. The recovery rate of SPE and LLE techniques were 94 and 80% respectively.
Full-Text [PDF 148 kb]   (2941 Downloads)    
Type of Study: General | Subject: Interdisciplinary (Educational Management, Educational research, Statistics, Medical education
Received: 2003/01/1 | Published: 2003/03/15

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.