<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Pejouhesh dar Pezeshki  (Research in Medicine)</title>
<title_fa>پژوهش در پزشکی</title_fa>
<short_title>Research in Medicine</short_title>
<subject>Medical Sciences</subject>
<web_url>http://pejouhesh.sbmu.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>journal1</journal_hbi_system_user>
<journal_id_issn>1735-5311</journal_id_issn>
<journal_id_issn_online>2008-0506</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1396</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2018</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>42</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی تاثیر ناهمگنی بافت پستان بر متوسط دوز غد های در ماموگرافی با استفاده از شبیه سازی</title_fa>
	<title>Evaluation of effecting factors on average glandular dose in mammography using MCNPX simulation code</title>
	<subject_fa>فیزیک و مهندسی پزشکی</subject_fa>
	<subject>Physics and Medical Engineering</subject>
	<content_type_fa>عمومی</content_type_fa>
	<content_type>General</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;سابقه وهدف:&lt;/strong&gt; متوسط دوز غده ای، کرمای هوا در سطح ورودی (ESAK 1)و دوز غده ای بهنجار شده( DgN2 ) کمیت های اصلی در دوزیمتری ماموگرافی هستند. یکی از عوامل موثر بر DgN ترکیب بافت پستان است. در این مطالعه بافت پستان هم به صورت همگن و هم به صورت ناهمگن فرض شده است و تأثیر آن روی مقادیر DgN ارزیابی شده است.&lt;br&gt;
&lt;strong&gt;روش بررسی:&lt;/strong&gt; فانتوم های همگن پستان با نسبت های غده ای متفاوت شبیه سازی و مقادیر DgN برای این فانتوم همگن محاسبه شد. همچنین فانتوم ناهمگن پستان با در نظر گرفتن بافت چربی در زمینه فانتوم پستان که بافت غده ای به صورت کره هایی در آن حضو دارند، شبیه سازی شد. در این فانتوم نیز با تغییر شعاع بافت های غد های، نسبت غده ای فانتوم پستان تغییر داده شد و مقادیر DgN برای این فانتوم ناهمگن پستان نیز محاسبه و نتایج DgN در هر دو فانتوم همگن و ناهمگن پستان مقایسه و نتایج ارزیابی شد.&lt;br&gt;
&lt;strong&gt;یافته ها:&lt;/strong&gt; مقادیر DgN هم در فانتوم همگن پستان و هم در فانتوم ناهمگن پستان به نسبت غده ای پستان وابسته است و با افزایش نسبت غده ای مقادیر DgN به طور تقریبی به صورت خطی کاهش می یابند. ناهمگنی بافت پستان هم بر مقادیر DgN موثر است و این تأثیر خود به توزیع بافت غده ای درفانتوم ناهمگن پستان وابسته است؛ به گونه ای که با تغییر در توزیع بافت غده ای در فانتوم ناهمگن، درصد اختلاف DgN در فانتوم همگن و ناهمگن بین 47 - تا 77 + درصد متغیر است.&lt;br&gt;
&lt;strong&gt;نتیجه گیری:&lt;/strong&gt; در مطالعه هایی که در آن ضرایب DgN محاسبه شده است و این ضرایب در دوزیمتری ماموگرافی استفاده می شوند، تاکنون تأثیر ناهمگنی بافت پستان در نظر گرفته نشده است. با توجه به نتایج این مطالعه و محسوس بودن تأثیر ناهمگنی بافت غده و چربی در فانتوم پستان، ضریب تصحیحی برای مقادیر DgN پیشنهاد می شود.&lt;/p&gt;

&lt;div&gt;
&lt;div id=&quot;ftn1&quot;&gt;&lt;p&gt;&lt;/p&gt;&lt;/div&gt;
&lt;/div&gt;</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background&lt;/strong&gt;: Average Glandular Dose (AGD), entrance skin Air Kerma (ESAK), and Normalized Glandular Dose (DgN) are the main dosimetric quantities in mammography. Breast tissue composition is one of the factors affecting DgN values. In the present study, both homogeneous and heterogeneous breast tissues are assumed evaluating their impacts on DgN values.&lt;br&gt;
&lt;strong&gt;Methods&lt;/strong&gt;: Homogeneous breast phantom with different glandular fractions simulated and DgN values were calculated for the homogeneous phantom. Also, a heterogeneous breast phantom was simulated, considering that adipose tissue is in the background and glandular tissue is in the form of spheres which are in the breast phantom. By changing the radius of glandular tissue, the glandular fraction in heterogeneous breast phantom was changed. DgN values were also calculated for the heterogeneous breast phantom. DgN values in both homogeneous and heterogeneous breast phantoms were evaluated and the results were compared.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results&lt;/strong&gt;: DgN values depend on glandular fraction in both homogeneous and heterogeneous breast phantoms. As the glandular fraction increased, DgN values reduced almost linearly. Breast tissue heterogeneity affected DgN values, too; this effect is related to the distribution of the glandular tissue in the heterogeneous breast phantom, so that considering the change in the distribution of glandular tissue in the heterogeneous breast phantom, the relative difference in DgN value between homogeneous and heterogeneous phantom was variable between -47 to +77 percent.&lt;br&gt;
&lt;strong&gt;Conclusion&lt;/strong&gt;: In the previous studies in which DgN coefficients were calculated, and this coefficient was used in mammography dosimetry, the effect of heterogeneity of breast tissue was not considered. According to the results of the present study and the evident effect of heterogeneity 3 of glandular and fat tissue on the breast phantom, a correction factor to the DgN values is suggested.&lt;/p&gt;</abstract>
	<keyword_fa>ماموگرافی, شبیه سازی مونت کارلو, دوز غده ای بهنجار شده, کیست پستان</keyword_fa>
	<keyword>Mammography, Monte Carlo simulation, normalized glandular dose</keyword>
	<start_page>34</start_page>
	<end_page>39</end_page>
	<web_url>http://pejouhesh.sbmu.ac.ir/browse.php?a_code=A-10-3078-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Zeynab</first_name>
	<middle_name></middle_name>
	<last_name>Kave</last_name>
	<suffix></suffix>
	<first_name_fa>زینب</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کاوه</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mdeevband@yahoo.com</email>
	<code>100319475328460029077</code>
	<orcid>100319475328460029077</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه فیزیک و مهندسی پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی شهید پزشکی</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>محمد رضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>دیوبند</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mdeevband@yahoo.com</email>
	<code>100319475328460029076</code>
	<orcid>100319475328460029076</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>1.	گروه فیزیک و مهندسی پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی شهید پزشکی</affiliation_fa>
	 </author>


	<author>
	<first_name>Mehdi</first_name>
	<middle_name></middle_name>
	<last_name>Ghorbani</last_name>
	<suffix></suffix>
	<first_name_fa>مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>قربانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460029078</code>
	<orcid>100319475328460029078</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه فیزیک و مهندسی پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی شهید پزشکی</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
