<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Pejouhesh dar Pezeshki  (Research in Medicine)</title>
<title_fa>پژوهش در پزشکی</title_fa>
<short_title>Research in Medicine</short_title>
<subject>Medical Sciences</subject>
<web_url>http://pejouhesh.sbmu.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>journal1</journal_hbi_system_user>
<journal_id_issn>1735-5311</journal_id_issn>
<journal_id_issn_online>2008-0506</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1399</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2020</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>44</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>میزان دوز سطح پوست بیماران در رادیوگرافی‌های رایج در بیمارستان لقمان حکیم</title_fa>
	<title>Measuring the patient's skin dose in common radiographs in Loghman Hakim Hospital</title>
	<subject_fa>رادیولوژی</subject_fa>
	<subject>Radiology</subject>
	<content_type_fa>كاربردي</content_type_fa>
	<content_type>Applicable</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;مقدمه: &lt;/strong&gt;بیشترین پرتوگیری مردم از منابع مصنوعی از طریق دستگاه های پرتو نگاری تشخیصی به علت افزایش این آزمایشات در جامعه و اجتناب ناپذیر بودن این آزمایشات است. بهینه کردن میزان دوز ورودی پوست می&amp;shy;تواند نقش مهمی در کاهش پرتوگیری بیماران داشته باشد، که با پایش دوز ورودی پوست به عنوان یک پارامتر اصلی، قابل دستیابی است.&lt;br&gt;
&lt;strong&gt;مواد و روش بررسی:&lt;/strong&gt; &amp;nbsp;مطالعه توصیفی حاضر در بیمارستان دولتی لقمان حکیم تهران و با &amp;nbsp;235 بیمار&amp;nbsp; 100زن و 135مرد با بازه وزنی ۶۰&amp;plusmn;10 کیلو گرم &amp;nbsp;انجام شد. در این مطالعه دوز پوستی بیماران با استفاده از چهار دستگاه رادیولوژی&amp;nbsp; تشخیصی دارای استانداردهای سازمان انرژی اتمی، در 12 نمای رادیوگرافی رایج و با استفاده از تراشه&#8204;های ترمولومینسانس و دزیمتر گایگر مولر اندازه گیری شد.&lt;br&gt;
یافته ها: میانگین دوز پوست برای هر &amp;nbsp;روش رادیوگرافی مورد مطالعه برحسب میلی گری به ترتیب زیر به دست آمد: قفسه سینه (خلفی-قدامی)34/0، قفسه سینه (نیمرخ)85/1، شکم (قدامی-خلفی)31/3، لگن (قدامی-خلفی)79/4، مهره های گردنی(قدامی-خلفی)95/1، مهره های گردنی (نیمرخ)24/1، مهره های پشتی (قدامی-خلفی)38/2، مهره های پشتی (نیمرخ)68/4، مهره های کمری (قدامی-خلفی)95/3، مهره های کمری (نیمرخ)53/9، جمجمه (قدامی-خلفی)29/2 و جمجمه (نیمرخ)89/1.&lt;br&gt;
&lt;strong&gt;نتیجه گیری: &lt;/strong&gt;انجام دزیمتری در فواصل زمانی منظم و انجام دوره ای و منظم آزمایشات کنترل کیفی دستگاه های رادیوگرافی می تواند در فرآیند بهینه سازی، نظارت، کاهش دوز و&amp;nbsp; حفاظت از بیماران و همچنین ارزیابی آسیب های بالقوه ناشی از تشعشعات موثر باشد.&lt;br&gt;
&amp;nbsp;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div class=&quot;tw-swapa&quot;&gt;&lt;div class=&quot;DHcWmd&quot;&gt;&lt;/div&gt;&lt;/div&gt;

&lt;p style=&quot;margin: 0px; text-align: justify; line-height: normal;&quot;&gt;&lt;span new=&quot;&quot; style=&quot;margin: 0px; font-family:;&quot; times=&quot;&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;Background and purpose: Most exposure of people to artificial sources through diagnostic radiographs is due to the increase of these tests in the community and the inevitability of these tests. Optimizing the dose of skin inlet can play an important role in reducing radiation exposure, which can be achieved by monitoring the inlet dose as a key parameter.&lt;/font&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;margin: 0px 0px 13.33px; text-align: justify;&quot;&gt;&lt;span new=&quot;&quot; style=&quot;margin: 0px; line-height: 115%; font-family:;&quot; times=&quot;&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;The purpose of this study was to evaluate the rate of skin input dose in routine radiographic tests at Loghman Hakim Hospital in Tehran to compare the doses recommended by the International Commission for Protection against Radiation (ICRP) as well as, if possible, to provide simple guidelines for dose reduction and optimization. Patients with preserved image quality.&lt;/font&gt;&lt;/span&gt;&lt;br&gt;
&lt;span new=&quot;&quot; style=&quot;margin: 0px; line-height: 115%; font-family:;&quot; times=&quot;&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;Materials and Methods: This descriptive study was performed in Loghman Hakim public hospital in Tehran with 235 patients 100 females and 135 males with a weight range of &amp;plusmn; 10 kg. In this study, skin doses of patients were measured using four diagnostic radiographs of IAEA standards, in 12 common radiographic views using thermoluminescence chips and Geiger M&amp;uuml;ller dosimeter.&lt;/font&gt;&lt;/span&gt;&lt;br&gt;
&lt;span new=&quot;&quot; style=&quot;margin: 0px; line-height: 115%; font-family:;&quot; times=&quot;&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;Results: The doses of skin for each radiographic method in milligrays were as follows: Chest (posterior-anterior) 0.34, Chest (1.85), Abdominal (anterior-posterior) 3.31 , Hip (anterior-posterior) 4.79, cervical (anterior-posterior) 1.95, cervical vertebra (1.24), dorsal (anterior-posterior) 2.38, dorsal vertebrae (profile) 4.68), lumbar vertebrae 3.95, lumbar vertebrae 9.53, skull (antero-posterior) 29.2 and skull 1.89.&lt;/font&gt;&lt;/span&gt;&lt;br&gt;
&lt;span new=&quot;&quot; style=&quot;margin: 0px; line-height: 115%; font-family:;&quot; times=&quot;&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;Conclusion: This study shows that the rate of skin inlet dose in the twelve investigated facets was in accordance with the recommended doses and was in line with the standards provided by the International Commission for Protection against ICRP and also optimized the radiation parameters. And standardizing radiographic conditions by preserving the image quality will reduce the dose received by patients. In this regard, dosimetry at regular intervals and periodic and regular quality control tests of radiographic devices can be optimized, monitored, reduced dose. And protecting patients as well as assessing potential harm The object of radiation will be effective.&lt;/font&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin: 0px 0px 13.33px; text-align: justify;&quot;&gt;&lt;/p&gt;

&lt;p style=&quot;margin: 0px 0px 13.33px; text-align: justify;&quot;&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; new=&quot;&quot; style=&quot;margin: 0px; line-height: 115%; font-family:;&quot; times=&quot;&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;&amp;nbsp;&lt;/font&gt;&lt;/span&gt;&lt;/p&gt;</abstract>
	<keyword_fa>اشعه ایکس,حفاظت پرتویی,دوز سطج پوست,رادیولوژی تشخیصی</keyword_fa>
	<keyword>X-ray, Radiation Protection, Skin Dose, Diagnostic Radiology</keyword>
	<start_page>460</start_page>
	<end_page>465</end_page>
	<web_url>http://pejouhesh.sbmu.ac.ir/browse.php?a_code=A-10-3724-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>seyed mohammad</first_name>
	<middle_name></middle_name>
	<last_name>Hosseini</last_name>
	<suffix></suffix>
	<first_name_fa>سید محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حسینی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>s.mohammad.hos@gmail.com</email>
	<code>100319475328460028533</code>
	<orcid>100319475328460028533</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Skull Base Research Center, Loghman Hakim Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>مرکز تحقیقات قاعده جمجمه، بیمارستان لقمان حکیم، دانشگاه علوم پزشکی شهید بهشتی، تهران ، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hossein </first_name>
	<middle_name></middle_name>
	<last_name>Yousefi-Banaem</last_name>
	<suffix></suffix>
	<first_name_fa>حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یوسفی بنائم</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460028534</code>
	<orcid>100319475328460028534</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Skull Base Research Center, Loghman Hakim Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>مرکز تحقیقات قاعده جمجمه، بیمارستان لقمان حکیم، دانشگاه علوم پزشکی شهید بهشتی، تهران ، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name> Hooman </first_name>
	<middle_name></middle_name>
	<last_name>Bahrami Motlagh</last_name>
	<suffix></suffix>
	<first_name_fa>هومن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بهرامی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460028535</code>
	<orcid>100319475328460028535</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Radiology, School of Medicine, Loghman Hakim Hospital, Shahid Beheshti University of Medical Sciences</affiliation>
	<affiliation_fa>استادیار گروه رادیولوژی، دانشگاه علوم پزشکی شهید بهشتی، بیمارستان لقمان حکیم</affiliation_fa>
	 </author>


	<author>
	<first_name>Mehdi </first_name>
	<middle_name></middle_name>
	<last_name>Salehi Barough</last_name>
	<suffix></suffix>
	<first_name_fa>مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صالحی باروق</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460028536</code>
	<orcid>100319475328460028536</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Radiation Engineering, Central Tehran Branch, Islamic Azad University, Tehran, Iran</affiliation>
	<affiliation_fa>گروه مهندسی هسته ای- مهندسی پرتو پزشکی واحد تهران مرکزی، دانشگاه آزاد اسلامی، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
